087-979-8880 salekuplus@gmail.com
ติดตามคำสั่งซื้อ แจ้งเตือน
ตะกร้าสินค้า
ตะกร้าสินค้าว่างเปล่า
เลือกซื้อสินค้า
2904951
Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block - 2904951

2904951

-

3-7 วัน
2701189
Program and configuration memory, plug-in, 2 Gbytes with license key for function block libraries, e.g., for: SNMP, SQL, wireless, motion functions, etc. - 2701189

2701189

-

3-7 วัน
2963938
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, 1 or 2-channel operation, 2 enabling current paths, nominal input voltage: 24 V AC/DC, plug-in spring-cage terminal block - 2963938

2963938

-

3-7 วัน
2904955
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block - 2904955

2904955

-

3-7 วัน
2901417
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 42 ... 48 V AC/DC, plug-in spring-cage terminal block - 2901417

2901417

-

3-7 วัน
2986957
Safe coupling relay for SIL 3 high and low-demand applications, couples digital output signals to the I/O, 2 enabling current paths, 1 signal contact, module for safe state off applications, integrated test pulse filter, plug-in spring-cage terminal block, width: 17.5 mm - 2986957

2986957

-

3-7 วัน
2981842
Safe coupling relay with force-guided contacts, 3 N/O contacts, 3 N/C contacts, plug-in spring-cage terminal block, width: 22.5 mm - 2981842

2981842

-

3-7 วัน
2700575
Safety relay for two-hand control devices according to EN 574 type IIIC, up to SILCL 3, Cat. 4, PL e, synchronous activation monitoring < 0.5 s, 2 enabling current paths, US = 24 V DC, plug-in spring-cage terminal block - 2700575

2700575

-

3-7 วัน
2904953
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block - 2904953

2904953

-

3-7 วัน
2988780
Program and configuration memory, plug-in, 256 MB - 2988780

2988780

-

3-7 วัน
2963941
Safety Relay 5A 3NO + 1NC DIN Rail Mount

2963941

-

3-7 วัน
2986562
Coupling relay for SIL 3 low-demand applications, couples digital output signals to the I/O, 1 enabling current path, module for F&G applications, test pulse filter, plug-in spring-cage terminal block, width: 17.5 mm - 2986562

2986562

-

3-7 วัน
2900526
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, 1 or 2-channel operation, 2 enabling current paths, nominal input voltage: 24 V AC/DC, plug-in spring-cage terminal block - 2900526

2900526

-

3-7 วัน
2901431
Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, plug-in spring-cage terminal block - 2901431

2901431

-

3-7 วัน
2981224
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with fixed 3.0 s dropout delay, plug-in screw connection terminal blocks - 2981224

2981224

-

3-7 วัน
2981813
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat.4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s ... 30 s, plug-in spring-cage terminal block - 2981813

2981813

-

3-7 วัน
2963954
Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 4 enabling current paths, US = 24 V AC/DC, plug-in spring-cage terminal block - 2963954

2963954

-

3-7 วัน
2403298
Program and configuration memory, plug-in, 2 GB, with license key and application program for easy web-based configuration and startup of a SafetyBridge solution including communication via Modbus/TCP, PROFINET, and e-mail. - 2403298

2403298

-

3-7 วัน
2963925
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in spring-cage terminal block - 2963925

2963925

-

3-7 วัน
2700351
Axioline E-IO-Link/analog converter for connecting an analog actuator, 4 mA ... 20 mA, M12 fast connection technology, straight version - 2700351

2700351

-

3-7 วัน
2903255
Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in spring-cage terminal block - 2903255

2903255

-

3-7 วัน
2708753
V.24 (RS-232) zero modem connector - 2708753

2708753

-

3-7 วัน
2963996
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single- or two-channel operation, 8 enabling current paths, US = 24 V AC/DC, plug-in spring-cage terminal block - 2963996

2963996

-

3-7 วัน
2700564
Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in spring-cage terminal block - 2700564

2700564

-

3-7 วัน