087-979-8880 salekuplus@gmail.com
ติดตามคำสั่งซื้อ แจ้งเตือน
ตะกร้าสินค้า
ตะกร้าสินค้าว่างเปล่า
เลือกซื้อสินค้า
2981635
Cable adapter for PSR over-speed safety relays (PSR-RSM4 and PSR-MM30), 15/8-pos., cable length: 2.5 m, for controller: Siemens - 2981635

2981635

-

3-7 วัน
2981266
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with fixed 5.0 s dropout delay, plug-in screw connection terminal blocks - 2981266

2981266

-

3-7 วัน
2902933
Universal termination carrier for connecting 16 MINI Analog signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) - 2902933

2902933

-

3-7 วัน
2981897
Adapter for PSR-RSM, hardware interface for HTL encoder - signal conditioning - 2981897

2981897

-

3-7 วัน
1539570
Short-circuit plug, for bridging unused slots on PSR-SACB sensor box for safety limit switch - 1539570

1539570

-

3-7 วัน
1009831
Safety relay for emergency stop, safety doors and light grids up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, US = 24 V DC, pluggable screw terminal block - 1009831

1009831

-

3-7 วัน
2909570
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, offers motor protection and emergency stop up to SIL 3/PL e. Possible group shut-down, supply, and relay extension via DIN rail connector. - 2909570

2909570

-

3-7 วัน
1050192
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration. - 1050192

1050192

-

3-7 วัน
1052464
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, order configuration. - 1052464

1052464

-

3-7 วัน
2924320
Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 - 20 mA signals. Freely programmable, 3-way electrical isolation. - 2924320

2924320

-

3-7 วัน
2924032
Ex i output signal conditioner, HART. Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, spring-cage connection. - 2924032

2924032

-

3-7 วัน
2811459
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL. - 2811459

2811459

-

3-7 วัน
2904090
Signal Isolator, 4...20mA, 4...20mA, 2865382, 12.5 x 99 x 114.5 mm

2904090

-

3-7 วัน
2924676
Signal Isolator and Repeater, 24V, 5-Way, MACX MCR

2924676

-

3-7 วัน
2924045
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via a relay output (PDT contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2. - 2924045

2924045

-

3-7 วัน
2924090
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2. - 2924090

2924090

-

3-7 วัน
2811572
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL. - 2811572

2811572

-

3-7 วัน
2924838
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4...20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL. - 2924838

2924838

-

3-7 วัน
2908661
The output-loop-powered temperature transmitter transmits up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors via HART communication or 4 ... 20 mA, configurable. SIL 2/3, intrinsic safety, Push-in connection. - 2908661

2908661

-

3-7 วัน
2811585
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL. - 2811585

2811585

-

3-7 วัน
2909556
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, offers motor protection, ATEX, and emergency stop up to SIL 3. Possible group shut-down, supply, and relay extension via DIN rail connector. - 2909556

2909556

-

3-7 วัน
1050222
Temperature Transducer, MACX MCR, -200 ... 850°C

1050222

-

3-7 วัน
1050233
Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4...20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, SIL. - 1050233

1050233

-

3-7 วัน
2924317
Temperature transducer, converts signals from resistance thermometers and resistors into 0/4-20 mA signals. Freely programmable, 3-way electrical isolation, custom-configured. - 2924317

2924317

-

3-7 วัน