ABB Jokab SSR10 Safety Switch Safety Relay 24VDC 2TLA010050R0000

2TLA010050R0000

Safety Relay

เอกสาร

-

จัดส่งภายใน 2–5 วัน

รายละเอียดสินค้า

ABB Jokab SSR10

Safety Switch Safety Relay 24VDC 2TLA010050R0000

คุณสมบัติ Value
Supply Voltage 24V dc
Number of Channels 3
Safety Contacts 4
Function Safety Switch
Auxiliary Contacts 3
Reset Method Multi-Reset
Range Sentry
Safety Category ISO 13849-1 4
PL ISO 13849-1 e
SIL IEC 61508 3
Configurable Yes
Terminal Type Screw
Width 120mm
Depth 120mm
Series SSR10
Performance Level e
Length 22.5mm

 

 

Sentry SSR10 2TLA010050R0000 SSR Safety relay Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.
Sentry SSR10P 2TLA010050R0001 SSR Safety relay Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.
Sentry SSR10M 2TLA010050R0100 SSR Safety relay Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals.
For monitoring of safety devices with contacts, 2 equivalent channels.
Manual or automatic reset selectable by switch on front.
Sentry SSR10MP 2TLA010050R0101 SSR Safety relay Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals.
For monitoring of safety devices with contacts, 2 equivalent channels.
Manual or automatic reset selectable by switch on front.
Sentry SSR20 2TLA010051R0000 SSR Safety relay Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals.
For monitoring of two-hand devices.
Manual or automatic reset selectable by switch on front.
Sentry SSR20P 2TLA010051R0001 SSR Safety relay Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals.
For monitoring of two-hand devices.
Manual or automatic reset selectable by switch on front.
Sentry SSR20M 2TLA010051R0100 SSR Safety relay Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals.
For monitoring of two-hand devices.
Manual or automatic reset selectable by switch on front.
Sentry SSR20MP 2TLA010051R0101 SSR Safety relay Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals.
For monitoring of two-hand devices.
Manual or automatic reset selectable by switch on front.
Sentry SSR32 2TLA010052R0400 SSR Safety relay Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.he two delayed NO relay outputs have an OFF-delay time of 0,5 second.
Sentry SSR32P 2TLA010052R0401 SSR Safety relay Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.
The two delayed NO relay outputs have an OFF-delay time of 0,5 second.
Sentry SSR42 2TLA010053R0400 SSR Safety relay Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.
The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds.
Sentry SSR42P 2TLA010053R0401 SSR Safety relay Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals.
For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs.
Manual or automatic reset selectable by switch on front.
The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds.