Digital monitoring relay Speed monitoring from 50 to 60 rpm for 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay 1 NO Tripping delay 0.1 s Without hysteresis 1 change-over c
3UG4651-1AA38-0AA8-ZX95
-
3-7 วัน
Speed Monitoring Relay
3UG4651-1AW30
-
3-7 วัน
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99
3UG4651-2AA30
-
3-7 วัน
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer sp
3UG4651-2AW30
-
3-7 วัน
Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, scr
3UG4815-1AA40
-
3-7 วัน
Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, spr
3UG4815-2AA40
-
3-7 วัน
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-ove
3UG4816-1AA40
-
3-7 วัน
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-ove
3UG4816-2AA40
-
3-7 วัน
Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC Overcurrent and undercurrent Transformer scaling factor Hysteresis 0.01 to 5.0 A ON-delay time Tripping delay time 1 change-over contact, screw terminal
3UG4822-1AA40
-
3-7 วัน
Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC Overcurrent and undercurrent Transformer scaling factor Hysteresis 0.01 to 5.0 A ON-delay time Tripping delay time 1 change-over contact, spring-type connection system
3UG4822-2AA40
-
3-7 วัน
Digital monitoring relay for residual current monitoring with residual-current transformer 3UL23 for IO-Link Setting range 0.03 A to 40 A separate for warning threshold and switch-off value ON delay and tripping delay 0 to 999.9 s Shutdown hysteresis up t
3UG4825-1CA40
-
3-7 วัน
Digital monitoring relay for residual current monitoring with residual-current transformer 3UL23 for IO-Link Setting range 0.03 A to 40 A separate for warning threshold and switch-off value ON delay and tripping delay 0 to 999.9 s Shutdown hysteresis up t
3UG4825-2CA40
-
3-7 วัน
Digital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Overvoltage and undervoltage Hysteresis 0.1 to 300 V ON-delay time Tripping delay time 1 change-over contact, screw terminal
3UG4832-1AA40
-
3-7 วัน
Digital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Overvoltage and undervoltage Hysteresis 0.1 to 300 V ON-delay time Tripping delay time 1 change-over contact, spring-type connection system
3UG4832-2AA40
-
3-7 วัน
Digital monitoring relay cos phi and current monitoring for IO-Link 90...690 V AC, 0.2...10 A 0vershoot and undershoot ON-delay time Tripping delay time Hysteresis 0.1 to 3.0 A 2 change-over contacts, screw terminal
3UG4841-1CA40
-
3-7 วัน
Digital monitoring relay cos phi and current monitoring for IO-Link 90...690 V AC, 0.2...10 A 0vershoot and undershoot ON-delay time Tripping delay time Hysteresis 0.1 to 3.0 A 2 change-over contacts, spring-type connection system
3UG4841-2CA40
-
3-7 วัน
Digital monitoring relay Speed monitoring for IO-Link from 0.1...2200 rpm 0vershoot and undershoot ON-delay time Tripping delay time Hysteresis 0.1 to 99 rpm 1 change-over contact, screw terminal
3UG4851-1AA40
-
3-7 วัน
Digital monitoring relay Speed monitoring for IO-Link from 0.1...2200 rpm 0vershoot and undershoot ON-delay time Tripping delay time Hysteresis 0.1 to 99 rpm 1 change-over contact, spring-type connection system
3UG4851-2AA40
-
3-7 วัน
cover, sealable, for insulation monitoring relay 3UG4581 and 3UG4582 Width 22.5 mm
3UG4981-0C
-
3-7 วัน
cover, sealable, for insulation monitoring relay 3UG4583 Width 45 mm
3UG4983-0C
-
3-7 วัน
Voltage reducer module for insulation monitoring relay 3UG4583 for expanding the supply voltage range to 690 V AC and 1000 V DC screw terminal
3UG4983-1A
-
3-7 วัน
DC load monitoring relay for PROFINET, max. 2x8 A / 1x16 A DC, max. 800 V Width: 22.5 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operati
3UG5461-1AA40
-
3-7 วัน
DC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operating hours
3UG5462-1AA40
-
3-7 วัน
Temperature monitoring relay PT100, Overshoot 1 threshold value, Width 22.5 mm -50 ?C to 50 ?C 24 V AC/DC 1 NO + 1 NC, quiescent current principle screw terminal