Auxiliary switch on the front, 3 NO + 1 NC Current path 1 NO, 1 NC, 1 NO, 1 NO for contactor relays Size S00 Ring cable lug connection 53/54, 63/64, 73/74, 83/84 Physically coded; only with contactor relays 3RH2140* and 3RH2440* can be combined (according
3RH2911-4GA31
-
3-7 วัน
Auxiliary switch on the front, 4 NO Current path 1 NO, 1 NO, 1 NO, 1 NO for contactor relays Size S00 Ring cable lug connection 53/54, 63/64, 73/74, 83/84 Physically coded; only with contactor relays 3RH2140* and 3RH2440* can be combined (according to EN
3RH2911-4GA40
-
3-7 วัน
Auxiliary switch on the front, 1 NC Current path 1 NC for 3RH and 3RT Ring cable lug connection .1/.2
3RH2911-4HA01
-
3-7 วัน
Auxiliary switch on the front, 2 NC Current path 1 NC, 1 NC for 3RH and 3RT Ring cable lug connection .1/.2, .1/.2
3RH2911-4HA02
-
3-7 วัน
Auxiliary switch on the front, 3 NC Current path 1 NC, 1 NC, 1 NC for 3RH and 3RT Ring cable lug connection .1/.2, .1/.2, .1/.2
3RH2911-4HA03
-
3-7 วัน
Auxiliary switch on the front, 1 NO Current path 1 NO for 3RH and 3RT Ring cable lug connection .3/.4
3RH2911-4HA10
-
3-7 วัน
Auxiliary switch on the front, 1 NO + 1 NC Current path 1 NC, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .3/.4
3RH2911-4HA11
-
3-7 วัน
Auxiliary switch on the front, 1 NO + 2 NC Current path 1 NC, 1 NC, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .1/.2, .3/.4
3RH2911-4HA12
-
3-7 วัน
Auxiliary switch on the front, 1 NO + 3 NC Current path 1 NC, 1 NC, 1 NC, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .1/.2, .1/.2, .3/.4
3RH2911-4HA13
-
3-7 วัน
Auxiliary switch on the front, 2 NO Current path 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .3/.4, .3/.4
3RH2911-4HA20
-
3-7 วัน
Auxiliary switch on the front, 2 NO + 1 NC Current path 1 NC, 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .3/.4, .3/.4
3RH2911-4HA21
-
3-7 วัน
Auxiliary switch on the front, 2 NO + 2 NC Current path 1 NC, 1 NC, 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .1/.2, .3/.4, .3/.4
3RH2911-4HA22
-
3-7 วัน
Auxiliary switch on the front, 3 NO Current path 1 NO, 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .3/.4, .3/.4, .3/.4
3RH2911-4HA30
-
3-7 วัน
Auxiliary switch on the front, 3 NO + 1 NC Current path 1 NC, 1 NO, 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .1/.2, .3/.4, .3/.4, .3/.4
3RH2911-4HA31
-
3-7 วัน
Electron. contr. auxiliary switch on the front, 2 NC Current path 1 NC, 1 NC, for 3RH and 3RT Ring cable lug connection .1/.2, --/--, --/--, .1/.2
3RH2911-4NF02
-
3-7 วัน
Electron. contr. auxiliary switch on the front, 1 NO + 1 NC Current path 1 NO, 1 NC, for 3RH and 3RT Ring cable lug connection .3/.4, --/--, --/--, .1/.2
3RH2911-4NF11
-
3-7 วัน
Electron. contr. auxiliary switch on the front, 2 NO, Current path 1 NO, 1 NO for 3RH and 3RT Ring cable lug connection .3/.4, --/--, --/--, .3/.4
3RH2911-4NF20
-
3-7 วัน
Coupling link for front-end mounting to AC, DC, AC / DC Contactors, 3RT2 S00-S3, 24 V DC Control, screw terminal
3RH2914-1GP11
-
3-7 วัน
Coupling link for front-end mounting to AC, DC, AC / DC Contactors, 3RT2 S00-S3, 24 V DC Control, Spring-type terminal
3RH2914-2GP11
-
3-7 วัน
Auxiliary switch lateral, 2 NO Current path 1 NO, 1 NO for 3RH and 3RT screw terminal R: 33/34, 43/44 L: 53/54, 63/64
3RH2921-1DA20
-
3-7 วัน
Auxiliary switch lateral, 2 NO Current path 1 NO, 1 NO for 3RH and 3RT spring-type terminal R: 33/34, 43/44 L: 53/54, 63/64
3RH2921-2DA20
-
3-7 วัน
Auxiliary switch lateral, 1 NO + 1 NC Current path 1 NC, 1 NO for 3RH and 3RT Ring cable lug connection R: 31/32, 43/44 L: 51/52, 63/64
3RH2921-4DA11
-
3-7 วัน
Coupling link for direct coil mounting, 24 V DC, 1 NO, 1 NC for motor contactors size S0 screw terminal connection B1/B2 for 1 NO
3RH2924-1GP11
-
3-7 วัน
Electronic Timing Relay Suitable for 3RT2 Size S00/S0 Contactors