Unit | Name | No. of I/O points |
LCD display |
Power supply voltage |
Inputs | Outputs | Buttons, calendar, and clock |
Analog input |
Model | ||
---|---|---|---|---|---|---|---|---|---|---|---|
CPU Units |
Standard LCD type |
10 | Yes | 100 to 240 VAC |
6 | 100 to 240 VAC |
4 | Relays | Yes | No | ZEN-10C1AR-A-V2 |
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-10C1DR-D-V2 | ||||||||
Transistors | ZEN-10C1DT-D-V2 | ||||||||||
20 | 100 to 240 VAC |
12 | 100 to 240 VAC |
8 | Relays | No | ZEN-20C1AR-A-V2 | ||||
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-20C1DR-D-V2 | ||||||||
Transistors | ZEN-20C1DT-D-V2 | ||||||||||
LED type without display *1 |
10 | No | 100 to 240 VAC |
6 | 100 to 240 VAC |
4 | Relays | No | No | ZEN-10C2AR-A-V2 | |
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-10C2DR-D-V2 | ||||||||
Transistors | ZEN-10C2DT-D-V2 | ||||||||||
20 | 100 to 240 VAC |
12 | 100 to 240V AC |
8 | Relays | No | ZEN-20C2AR-A-V2 | ||||
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-20C2DR-D-V2 | ||||||||
Transistors | ZEN-20C2DT-D-V2 | ||||||||||
Economy type (Expansion I/O Units cannot be connected) |
10 | Yes | 100 to 240 VAC |
6 | 100 to 240 VAC |
4 | Relays | Yes | No | ZEN-10C3AR-A-V2 | |
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-10C3DR-D-V2 | ||||||||
20 | 100 to 240 VAC |
12 | 100 to 240 VAC |
8 | Relays | No | ZEN-20C3AR-A-V2 | ||||
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-20C3DR-D-V2 | ||||||||
Communi- cations type |
9 | 100 to 240 VAC |
6 | 100 to 240 VAC |
3 | Relays | No | ZEN-10C4AR-A-V2 | |||
12 to 24 VDC |
12 to 24 VDC |
Yes | ZEN-10C4DR-D-V2 | ||||||||
ZEN Kit | Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual. | ZEN-KIT01-EV4 *4 | |||||||||
Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual. | ZEN-KIT02-EV4 *4 | ||||||||||
Expansion I/O Units |
8 | --- | 100 to 240 VAC |
4 | 100 to 240 VAC |
4 | Relays | --- | ZEN-8E1AR *2 *3 | ||
12 to 24 VDC |
12 to 24 VDC |
ZEN-8E1DR *2 | |||||||||
--- | Transistors | ZEN-8E1DT *2 |
CONTROL LOG 6 IN 4 OUT 100-240V
ZEN-STARTER01-V2
เอกสาร
THB0.00
จัดส่งภายใน 2–5 วัน
รายละเอียดสินค้า
CONTROL LOG 6 IN 4 OUT 100-240Vข้อมูลสินค้า
CPU Units and Expansion I/O Units
*1. Programming is not possible using only the CPU in the LED-type CPU Unit. ZEN Support Software or a Memory Cassette
is required.
*2. Cannot be connected to pre-V1 and V1 CPU Units.
*3. The ZEN-8E1AR cannot be connected to a CPU Unit with DC power supply.
*4. Product no longer available to order.
is required.
*2. Cannot be connected to pre-V1 and V1 CPU Units.
*3. The ZEN-8E1AR cannot be connected to a CPU Unit with DC power supply.
*4. Product no longer available to order.
Power Supply Unit
Power ratings | Input voltage | Output voltage | Output current | Model |
---|---|---|---|---|
30 W | 100 to 240 VAC | 24 VDC | 1.3 A | ZEN-PA03024 |
Note: Product no longer available to order.
Refer to the ZEN-PA03024 Datasheet (Cat. No. L103) for detailed specifications.
Refer to the ZEN-PA03024 Datasheet (Cat. No. L103) for detailed specifications.
Accessories (Order Separately)
Name | Specifications | Remarks | Model | ||
---|---|---|---|---|---|
Memory Cassette |
EEPROM (for data security and copying) |
Enables programs and parameter settings to be saved or copied to another ZEN. *1 |
ZEN-ME01 | ||
LCD-type CPU Unit with display *2 |
LED-type CPU Unit without display *3 |
||||
Transfer from ZEN to Memory |
Supported | Not supported | |||
Transfer from Memory Cassette to ZEN |
Supported | Automatic transfer when power turned ON |
|||
Memory Cassette initialization |
Supported | Not supported | |||
Connecting Cable |
2 m RS-232C (9-pin Dsub connector) |
For notebook computers that do not have an RS-232C serialport, connect the computer to the ZEN by connecting an OMRON CS1W-CIF31 USB-Serial Conversion Cable to the ZEN-CIF01 Connecting Cable. |
ZEN-CIF01 | ||
USB-Serial Conversion Cable |
0.5m USB (type A plug, male), RS-232C (D-sub 9-pin, male) |
Attached drivers (On CD-ROM) | CS1W-CIF31 | ||
Battery Unit | 10 years min. Battery life (at 25°C) |
Ladder programs and parameter settings are saved to the CPU Unit EEP- ROM but calendar, clock, and holding timer bits and holding timer/counter present values are held by the capacitor. Therefore, if the power supply is interrupted for 2 days or more (at 25°C), this data will be reset. Use a Battery Unit for systems where the power supply may be interrupted for long periods. |
ZEN-BAT01 | ||
ZEN Support Software |
Runs on Windows 95, 98, 2000, Me, XP, NT4.0 Service Pack3, Vista (32bit), Windows7 (32-bit/64-bit version), Windows10 (32-bit/64-bit version) |
Specifically designed for the ZEN (CD-ROM). | ZEN-SOFT01-V4 |
*1. Memory Cassettes created using a CPU Unit can be read to other CPU Units, regardless of which model is used.
Restrictions, apply, however, to the functions that can be used, depending on the CPU Unit version combination. For
details, refer to Memory Cassette and CPU Unit Combinations on Data Sheet.
*2. Standard LCD-type, Economy-type, and Communications-type CPU Units (i.e., excluding ZEN-[]C2[][]-[]-V2 models).
*3. LED-type CPU Unit without display (i.e., ZEN-[]C2[][]-[]-V2 models).
Restrictions, apply, however, to the functions that can be used, depending on the CPU Unit version combination. For
details, refer to Memory Cassette and CPU Unit Combinations on Data Sheet.
*2. Standard LCD-type, Economy-type, and Communications-type CPU Units (i.e., excluding ZEN-[]C2[][]-[]-V2 models).
*3. LED-type CPU Unit without display (i.e., ZEN-[]C2[][]-[]-V2 models).
Mounting Accessories (Order Separately)
Name | Specifications | Model |
---|---|---|
Mounting Track | 50 cm (l) × 7.3 mm (t) | PFP-50N |
1 m (l) × 7.3 mm (t) | PFP-100N | |
1 m (l) × 16 mm (t) | PFP-100N2 | |
End Plate | PFP-M | |
Spacer | PFP-S |