สอบถามสินค้าโทร. 087-979-8880.
Cloud HMI, ARM Cortex A8 600MHz, 1024x748, 256MB RAM, 256MB Flash, real time clock, Com1: RS-232, Com2: RS-485 2w/4w, Com3: RS-485 2w, EasyAccess 2.0
Memory
|
Storage (MB)
|
256
|
RAM (MB)
|
256
|
|
Processor
|
ARM Cortex A8 600 MHz
|
|
I/O Port
|
SD Card Slot
|
SD/SDHC
|
USB Host
|
USB 2.0 x 1
|
|
USB Client
|
||
Ethernet
|
10/100/1G x 2
|
|
COM Port
|
COM1 RS-232, COM2 RS-485 2W/4W, COM3RS-485 2W
|
|
CAN Bus
|
N/A
|
|
HDMI
|
N/A
|
|
RTC
|
|
Built-in (CR 1225 3V lithium battery)
|
Power
|
Input Power
|
24±20% VDC
|
Power Consumption
|
230mA@24V
|
|
Power Isolation
|
Built-in
|
|
Voltage Resistance
|
500 VAC (1 min)
|
|
Isolation Resistance
|
Exceed 50 MΩ at 500 VDC
|
|
Vibration Endurance
|
10 to 25 Hz (X, Y, Z directions 2 G 30 mins)
|
|
Specification
|
Enclosure
|
Plastic
|
Dimension (inch)
|
5.12 x 4.53 x 1.06
|
|
Weight (lb)
|
0.4
|
|
Mount
|
35 mm Din rail mounting
|
|
Storage Temperature
|
-4°F~158°F
|
|
Operating Temperature
|
-4°F~131°F
|
|
Relative Humidity
|
10%~90% RH (non-condensing)
|
|
Software
|
|
Server/Client HMI architecture
This Weintek cMT series from Weintek offfers a number of solutions:
Solution 1:
Smart communication gateway with data processing functions of an HMI which can quickly help you build IIot solutions.
Get notified on a mobile phone, EasyAccess 2.0 can remotely debug or update devcies or remote monitoring of HMI's with cMT Viewer APP.
The HMI is not just for operating machines or collecting and managing data. It is a key player in IIoT as a Communication Gateway. The data in the device connected to HMI can be published to IIoT system.
Solution 2:
You can control the HMI and execute the third party apps at the same time!
With EasyLauncher you can easily access third party apps including MS Office, PDF Reader, Media player and many more. Used with cMT VIewer you can monitor and control the HMI at the same time.
Solution 3:
You can have more flexible installations to operate your HMI!
You can install your cMT-SVR, which is dedicated to data processing and communication protocol conversion, and PLC in the same control cabinet. You can also install one or more cMT-iV5s located on any place of the machine for connecting to the same cMT-SVR.
Solution 4:
HMI is also an HMI server!
cMT3090/cMT3151 has a dual-core CPU greatly increasing data/graphic processing. You can use cMT Viewer to connect for monitoring and controlling.
cMT Viewer is running on cMT-iPC10/cMT-iPC15 or cMT-iV5.
The CMT series is a mobile solution with cMT Viewer and a remote solution with EasyAccess 2.0.